Test ID TPRPS ThinPrep Screen, Varies
Ordering Guidance
1. Mayo Clinic Laboratories' clients need prior laboratory approval to order cytology testing.
2. If the patient has been previously diagnosed with an abnormal Pap result or is at high risk, consider ordering the diagnostic test TPRPD / ThinPrep Diagnostic, Varies.
3. Specimen submitted as endocervical curettage or endocervical brushing need to be ordered as CYTNG / Cytology Non-Gynecologic, Varies.
Necessary Information
1. An acceptable cytology request form must accompany specimen containers and include the following: patient's name, medical record number, date of birth, sex, source (exact location and procedure used), date specimen was taken, and name of ordering physician and pager number.
2. Submit any pertinent history or clinical information.
Specimen Required
Patient Preparation: For optimal interpretation, Pap smears should be collected near the middle of the menstrual cycle. Avoid douching, lubricant use, and sexual intercourse for 24 hours prior to specimen collection.
Only 1 aliquot may be removed from PreservCyt sample vial prior to performing the ThinPrep Pap test, regardless of the volume of the aliquot (maximum aliquot volume: 4 mL).
Submit only 1 of the following specimens:
Specimen Type: Cervical
Supplies: Thin Prep Media with Broom Kit (T056)
Container/Tube: ThinPrep
Specimen Volume: 16 mL
Collection Instructions:
1. Obtain adequate sampling from cervix using a broom-like collection device. If desired, use lukewarm to warm water and lubricate the speculum. Insert the central bristles of the broom into the endocervical canal deep enough to allow the shorter bristles to fully contact the ectocervix. Push gently and rotate the broom in a clockwise direction 5 times.
2. Rinse the broom as quickly as possible into the PreservCyt solution vial by pushing broom into bottom of vial 10 times, forcing the bristles apart.
3. As a final step, swirl broom vigorously to further release material. Discard the collection device.
4. Tighten cap on vial so that the torque line on the cap passes the torque line on the vial.
5. Specimen vial must be labeled with a minimum of 2 unique identifiers (patient's name and medical record number or date of birth).
6. Bag ThinPrep specimens individually as they have a tendency to leak during transport.
7. Place labels on the vial and on the bag.
Specimen Type: Ectocervix and endocervix
Supplies: Thin Prep Media with Spatula and Brush Kit (T434)
Container/Tube: ThinPrep
Specimen Volume: 16 mL
Collection Instructions:
1. Obtain an adequate sampling from the ectocervix using a plastic spatula. If desired, use lukewarm to warm water and lubricate the speculum. Select contoured end of plastic spatula and rotate it 360 degrees around the entire exocervix while maintaining tight contact with exocervical surface.
2. Rinse spatulas quickly as possible into the PreservCyt solution vial by swirling spatula vigorously in vial 10 times. Discard the spatula.
3. Next, obtain an adequate specimen from endocervix using an endocervical brush device. Insert the brush into the cervix until only the bottommost fibers are exposed. Slowly rotate one-quarter or one-half turn in one direction. Do not over rotate.
4. Rinse the brush as quickly as possible in the PreservCyt solution by rotating the device in the solution 10 times while pushing against the PreservCyt vial wall.
5. Swirl brush vigorously as final step to further release material. Discard the brush.
6. Tighten the cap so that the torque line on the cap passes the torque line on the vial.
7. Specimen vial must be labeled with a minimum of 2 unique identifiers (patient's name and medical record number or date of birth).
8. Bag ThinPrep specimens individually as they have a tendency to leak during transport.
9. Place labels on the vial.
Forms
Useful For
Screening for cervical carcinoma or intraepithelial lesions
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
TPSPC | Physician Interp Screen | No | No |
Testing Algorithm
If ThinPrep Pap results are abnormal, a pathologist will review the case at an additional charge.
Special Instructions
Method Name
ThinPrep Pap Cytology Screening by Light Microscopy
Reporting Name
ThinPrep ScreenSpecimen Type
VariesSpecimen Minimum Volume
See Specimen Required
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Ambient (preferred) | 42 days | THIN PREP |
Refrigerated | 42 days | THIN PREP |
Reference Values
Satisfactory for evaluation. Negative for intraepithelial lesion or malignancy.
Note: Abnormal results will be reviewed by a pathologist at an additional charge.
Day(s) Performed
Monday through Friday
Report Available
5 to 8 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
G0123 (Government Payers)
88142
88141-TPSPC (if appropriate)
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
TPRPS | ThinPrep Screen | 47527-7 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
71286 | Interpretation | 69965-2 |
71287 | Participated in the Interpretation | No LOINC Needed |
71288 | Report electronically signed by | 19139-5 |
71289 | Addendum | 35265-8 |
71290 | Gross Description | 22634-0 |
CY027 | Pap Test Source | 22633-2 |
CY028 | Clinical History | 22636-5 |
CY029 | Menstrual Status (LMP, PM, Pregnant) | 8678-5 |
CY030 | Hormone Therapy/Contraceptives | 8659-5 |
71574 | Disclaimer | 62364-5 |
71820 | Case Number | 80398-1 |