Test ID SGSS Synthetic Glucocorticoid Screen, Serum
Useful For
Confirming the presence of listed synthetic glucocorticoids (see Interpretation)
Confirming the cause of secondary adrenal insufficiency
This test is not useful for detection of fluticasone propionate.
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) Stable Isotope Dilution Analysis
Reporting Name
Synthetic Glucocorticoid Screen, SSpecimen Type
SerumOrdering Guidance
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 2 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
1.1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Frozen (preferred) | 14 days | |
Refrigerated | 7 days | ||
Ambient | 24 hours |
Reference Values
Negative
Cutoff concentrations
Betamethasone: 0.10 mcg/dL
Budesonide: 0.20 mcg/dL
Dexamethasone: 0.10 mcg/dL
Fludrocortisone: 0.10 mcg/dL
Megestrol acetate: 0.10 mcg/dL
Methylprednisolone: 0.10 mcg/dL
Prednisolone: 0.10 mcg/dL
Prednisone: 0.10 mcg/dL
Triamcinolone acetonide: 0.10 mcg/dL
Values for normal patients not taking these synthetic glucocorticoids should be less than the cutoff concentration (detection limit).
Day(s) Performed
Wednesday
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
80299
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
SGSS | Synthetic Glucocorticoid Screen, S | 43141-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
23593 | Betamethasone | 41745-1 |
23594 | Budesonide | 41747-7 |
23595 | Dexamethasone | 14062-4 |
23596 | Fludrocortisone | 41754-3 |
23600 | Megestrol Acetate | 41762-6 |
23601 | Methylprednisolone | 14186-1 |
23602 | Prednisolone | 12727-4 |
23603 | Prednisone | 12434-7 |
23605 | Triamcinolone Acetonide | 41767-5 |