Sign in →

Test ID HIP12 HIV-1/HIV-2 RNA Detection, Plasma


Ordering Guidance


This test is indicated for qualitative detection and differentiation of HIV-1 and HIV-2 infection in a person with indeterminate or inconclusive HIV serologic test results or who is suspected to be in the acute / early HIV infection stage (ie, "window period"). If serologic testing has not yet been performed on the patient, order either HVCOP / HIV-1 and HIV-2 Antigen and Antibody Routine Screen, Plasma or HIVDX / HIV-1 and HIV-2 Antigen and Antibody Diagnostic Evaluation, Plasma, where this test will automatically be added on depending on the results of the serologic test.



Shipping Instructions


1. Ship specimen frozen on dry ice.

2. If shipment will be delayed for more than 24 hours, freeze plasma specimen at -20 to -80° C until shipment on dry ice.



Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Lavender top (EDTA)

Submission Container/Tube: Plastic vial

Specimen Volume: 1.5 mL

Collection Instructions:

1. Centrifuge blood collection tube and aliquot plasma into plastic vial per collection tube manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).

2. Freeze aliquoted plasma for shipment.


Forms

If not ordering electronically, complete, print, and send a Microbiology Test Request (T244) with the specimen.

Useful For

Diagnosis of HIV-1 and/or HIV-2 infection in individuals with indeterminate or inconclusive HIV serologic test results

 

Diagnosis of HIV-1 and/or HIV-2 infection in individuals with acute or early HIV-1 and/or HIV-2 infection

 

Diagnosis of HIV-1 and/or HIV-2 infection in infants under 18 months of age who are born to HIV-infected mothers

Highlights

This test is to be used for qualitative detection and differentiation of HIV-1 and HIV-2 infection in a person with indeterminate or inconclusive HIV serologic test results or who is suspected to be in the acute/early HIV infection stage (ie, "window period").

Method Name

Real-Time Reverse Transcription-Polymerase Chain Reaction (RT-PCR)

Reporting Name

HIV-1/HIV-2 RNA Detect, P

Specimen Type

Plasma EDTA

Specimen Minimum Volume

0.8 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Plasma EDTA Frozen (preferred) 40 days
  Refrigerated  6 days

Reference Values

Undetected

Day(s) Performed

Monday through Saturday

Report Available

1 to 3 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

87535

87538

LOINC Code Information

Test ID Test Order Name Order LOINC Value
HIP12 HIV-1/HIV-2 RNA Detect, P 96557-4

 

Result ID Test Result Name Result LOINC Value
616340 HIV-1 RNA 25835-0
616341 HIV-2 RNA 69353-1

NY State Approved

Yes