Test ID F_10 Coagulation Factor X Activity Assay, Plasma
Useful For
Diagnosing deficiency of coagulation factor X, congenital or acquired
Evaluating hemostatic function in liver disease
Investigation of prolonged prothrombin time or activated partial thromboplastin time
Special Instructions
Method Name
Optical Clot-Based
Reporting Name
Coag Factor X Assay, PSpecimen Type
Plasma Na CitOrdering Guidance
Coagulation testing is highly complex, often requiring the performance of multiple assays and correlation with clinical information. For that reason, consider ordering a Coagulation Consultation.
Necessary Information
If priority specimen, mark request form, give reason, and request a call-back.
Specimen Required
Specimen Type: Platelet-poor plasma
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Light-blue top (3.2% sodium citrate)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. For complete instructions, see Coagulation Guidelines for Specimen Handling and Processing.
2. Within 4 hours of collection, centrifuge, transfer all plasma into a plastic vial, and centrifuge plasma again.
3. Aliquot plasma into separate plastic vial leaving 0.25 mL in the bottom of centrifuged vial.
4. Freeze plasma immediately (no longer than 4 hours after collection) at -20° C, or, ideally at or below -40° C.
Additional Information:
1. Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
2. Each coagulation assay requested should have its own vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Na Cit | Frozen | 14 days |
Reference Values
Adults: 70-150%
Normal, full-term newborn infants or healthy premature infants may have decreased levels (≥15-20%), which may not reach adult levels for 180 or more days postnatal.*
*See Pediatric Hemostasis References section in Coagulation Guidelines for Specimen Handling and Processing
Day(s) Performed
Monday through Friday
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
85260
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
F_10 | Coag Factor X Assay, P | 3218-5 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
F_10 | Coag Factor X Assay, P | 3218-5 |
Test Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.Report Available
1 to 3 daysNY State Approved
YesForms
If not ordering electronically, complete, print, and send a Coagulation Test Request (T753) with the specimen.