Test ID FRFIT Rabies Antibody Endpoint
Specimen Required
Specimen Type: Serum
Container/Tube: Red
Specimen Volume: 2 mL
Collection Instructions: Draw blood in a plain red-top tube(s), Spin down and send 2 mL of serum refrigerated in a plastic vial.
Note: 1. Serum gel tube is acceptable, but must be poured off into plastic vial.
2. Collection date is required.
Method Name
Serum Neutralization Fluorescent Antibody
Reporting Name
Rabies RFFIT Endpoint, SSpecimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 60 days |
Reference Values
Reportable range is 0.1 to 15.0 IU/mL
Less than 0.1 IU/mL: Below detection limit
In humans a results of 0.5 IU/mL or higher is considered an acceptable response to rabies vaccination according to the World Health Organization (WHO) guidelines; see WHO and Advisory Committee on Immunization Practices documents for additional guidance.
Day(s) Performed
Monday, Wednesday, Thursday
Report Available
21 to 35 daysPerforming Laboratory
RFFIT/K-State Rabies Laboratory Manhattan/K-State Innovation CenterCPT Code Information
86382
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
FRFIT | Rabies RFFIT Endpoint, S | 6524-3 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
Z2071 | Rabies Titer-Response | 6524-3 |