Test ID FEUCT Euglobulin Clot Lysis Time


Specimen Required


Specimen Type: Citrated plasma

Collection Container/Type: Light-blue top (sodium citrate)

Specimen Volume: 2 mL

Collection Instructions: Collect blood in 3/2% sodium citrate light blue top tube. Centrifuge within 30 minutes after collection, freeze immediately. Send 2 mL platelet-poor plasma in plastic vial frozen.

 

Note:

1. Prohibit exercise prior to drawing sample.

2. To avoid release of plasminogen activator, do not massage vein vigorously, pump fist excessively or leave tourniquet in place for a prolonged period.


Method Name

Clot Dissolution

Reporting Name

Euglobulin Clot Lysis Time

Specimen Type

Plasma Na Cit

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Plasma Na Cit Frozen 21 days

Reference Values

>60 min

Day(s) Performed

Wednesday

Report Available

5 to 18 days

Performing Laboratory

Quest Diagnostics Nichols Institute

CPT Code Information

85360

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FEUCT Euglobulin Clot Lysis Time 3244-1

 

Result ID Test Result Name Result LOINC Value
FEUCT Euglobulin Clot Lysis Time 3244-1

NY State Approved

Yes

Test Classification