Sign in →

Test ID FBNC1 Brazil Nut Component rBer e 1


Specimen Required


Specimen Type: Serum

Container/Tube: Red or SST

Specimen Volume: 0.5 mL

Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube is acceptable. Spin down and send 0.5 mL of serum refrigerated in a plastic vial.


Method Name

ImmunoCAP FEIA

Reporting Name

Brazil Nut Component rBer e 1

Specimen Type

Serum

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
  Frozen  365 days
  Ambient  28 days

Reference Values

<0.10 kU/L

Performing Laboratory

Eurofins Viracor

CPT Code Information

86008

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FBNC1 Brazil Nut Component rBer e 1 64963-2

 

Result ID Test Result Name Result LOINC Value
Z5672 Brazil Nut Component rBer e 1 64963-2
Z5673 Class 103065-9

NY State Approved

Yes

Day(s) Performed

Monday through Friday

Report Available

3 to 6 days