Test ID F100B S-100B Protein, Serum
Method Name
Quantitative Enzyme-Linked Immunosorbent Assay
Reporting Name
S-100B Protein, SerumSpecimen Type
SerumSpecimen Required
Collection Container/Tube: Red top or serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 2 mL serum
Collection Instructions:
1. Allow specimen to clot completely at ambient temperature.
2. Within 2 hours of collection, centrifuge and aliquot 2 mL of serum into a plastic vial.
3. Send refrigerate.
Specimen Minimum Volume
Serum: 0.5 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 7 days |
| Frozen | 90 days | |
| Ambient | 24 hours |
Reference Values
0 days to 5 months: ≤510 ng/mL
5 months to 10 months: ≤350 ng/mL
10 months to 25 months: ≤230 ng/L
25 months to 3 years: ≤170 ng/L
3 years to 19 years: ≤160 ng/L
19 years and older: 0-96 ng/L
Day(s) Performed
Tuesday
Performing Laboratory
ARUP LaboratoriesCPT Code Information
86316
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| F100B | S-100B Protein, Serum | 47275-3 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| Z2708 | S-100B Protein, S | 47275-3 |