Sign in →

Test ID EOSDF Chronic Eosinophilia, Diagnostic FISH, Varies


Ordering Guidance


This test is intended to be ordered when the entire chronic eosinophilia fluorescence in situ hybridization (FISH) panel is needed.

 

If limited chronic eosinophilia FISH probes are preferred, order EOSMF / Chronic Eosinophilia, Specified FISH, Varies.

 

At follow-up, targeted chronic eosinophilia probes can be evaluated based on the abnormalities identified in the diagnostic study. Order EOSMF/ Chronic Eosinophilia, Specified FISH, Varies. and request a specific probe to evaluate the known genomic abnormality.

 

Paraffin embedded tissue testing is not available for these probe sets.



Necessary Information


A reason for testing and a flow cytometry and/or a bone marrow pathology report should be submitted with each specimen. The laboratory will not reject testing if this information is not provided however, appropriate testing and interpretation may be compromised or delayed. If not provided, an appropriate indication for testing may be entered by Mayo Clinic Laboratories.



Specimen Required


Submit only 1 of the following specimens:

 

Preferred

Specimen Type: Bone marrow

Container/Tube:

Preferred: Yellow top (ACD)

Acceptable: Green top (heparin) or lavender top (EDTA)

Specimen Volume: 2-3 mL

Collection Instructions:

1. It is preferable to send the first aspirate from the bone marrow collection.

2. Invert several times to mix bone marrow.

3. Send bone marrow specimen in original tube. Do not aliquot.

 

Acceptable

Specimen Type: Blood

Container/Tube:

Preferred: Yellow top (ACD)

Acceptable: Green top (heparin) or lavender top (EDTA)

Specimen Volume: 6 mL

Collection Instructions:

1. Invert several times to mix blood.

2. Send whole blood specimen in original tube. Do not aliquot.


Useful For

Detecting a neoplastic clone associated with the common chromosome abnormalities seen in patients with myeloid/lymphoid neoplasms with eosinophilia and gene rearrangement (including PDGFRA, PDGFRB, FGFR1, JAK2, and ABL1).

 

Supporting the diagnosis of malignancy if a clone is present

 

An adjunct to conventional chromosome studies.

Testing Algorithm

This test includes a charge for the probe application, analysis, and professional interpretation of results for 5 probe sets (11 individual fluorescence in situ hybridization [FISH] probes). Additional charges will be incurred for all reflex or additional probe sets performed.

 

The panel includes testing for the following kinase activating chromosome abnormalities, using the following FISH probes:

4q12 deletion or rearrangement, FIP1L1, CHIC2 ,PDGFRA

5q32 rearrangement, PDGFRB

8p11.2 rearrangement, FGFR1

9p24.1 rearrangement, JAK2

9q34 rearrangement, ABL1

 

Appropriate ancillary probes may be performed at consultant discretion to render comprehensive assessment. Any additional probes will have the results included within the final report and will be performed at an additional charge.

 

In the absence of a CHIC2 deletion, if an extra or atypical CHIC2 or PDGFRA signal is identified, reflex testing will be performed using the PDGFRA break-apart probe set to evaluate for the presence or absence of a PDGFRA rearrangement.

 

If a PDGFRB rearrangement is identified, reflex testing using the PDGFRB/ETV6 probe set will be performed to evaluate for the presence or absence of t(5;12)(q32;p13) -PDGFRB::ETV6 fusion.

 

If an ABL1 rearrangement is identified, reflex testing using the ABL1/BCR probe set will be performed to evaluate for the presence or absence of t(9;22)(q34;q11.2) - ABL1::BCR fusion.

Method Name

Fluorescence In Situ Hybridization (FISH)

Reporting Name

Chronic Eosinophilia, Diag FISH

Specimen Type

Varies

Specimen Minimum Volume

Blood: 2 mL
Bone Marrow: 1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Ambient (preferred)
  Refrigerated 

Reference Values

An interpretive report will be provided.

Day(s) Performed

Monday through Friday

Report Available

7 to 10 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

88271 x11, 88275 x5, 88291 x1-FISH Probe, Analysis, Interpretation; 5 probe sets

88271 x2, 88275 x1–FISH Probe, Analysis; each additional probe set (if appropriate)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
EOSDF Chronic Eosinophilia, Diag FISH In Process

 

Result ID Test Result Name Result LOINC Value
609588 Result Summary 50397-9
609589 Interpretation 69965-2
609590 Result Table 93356-4
609591 Result 62356-1
GC080 Reason for Referral 42349-1
GC081 Specimen 31208-2
609592 Source 31208-2
609593 Method 85069-3
609594 Additional Information 48767-8
609595 Disclaimer 62364-5
609596 Released By 18771-6

NY State Approved

Yes

Forms

If not ordering electronically, complete, print, and send a Hematopathology/Cytogenetics Test Request (T726) with the specimen.