Sign in →

Test ID COVSQ Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), Spike Antibody, Semi-Quantitative, Serum


Ordering Guidance


This test will detect antibodies developed due to prior or current infection and will likely detect antibodies against spike glycoprotein of SARS-CoV-2 generated following vaccination. This test will not differentiate between the 2 events. The absence of antibodies in this assay does not rule out recent infection.

 

For confirmation of prior infection in the presence of vaccination, order COVTA / Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-Cov-2), Nucleocapsid, Total Antibody, Serum.

 

Molecular testing is recommended for diagnosis of COVID-19 in symptomatic patients. For more information see COVOO / Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) RNA Detection, Varies.

 

For the most up-to-date coronavirus disease 2019 (COVID-19) epidemiology and testing recommendations, visit www.cdc.gov/coronavirus/2019-ncov/index.html.



Necessary Information


1. Patient's race and ethnicity, as well as collection date, are required.

2. If ordering electronically, answers must be provided for the order entry questions.

3. If not ordering electronically, patient race and ethnicity must be provided on the request form.



Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial


Useful For

Aiding in the identification of individuals with an adaptive immune response to SARS-CoV-2, indicating prior infection or vaccination

 

Manufacture of COVID-19 convalescent plasma

Highlights

This test provides semi-quantitative detection of serum antibodies against the spike glycoprotein of the SARS-CoV-2, the causative agent of COVID-19.

 

This test is intended for use as an aid in identifying individuals with an adaptive immune response to SARS-CoV-2, indicating prior infection and/or vaccination.

 

Fact sheets for this emergency use authorization assay can be found at the following links:

For healthcare providers: www.fda.gov/media/144035/download

For patients: www.fda.gov/media/144036/download

Method Name

Electrochemiluminescence Immunoassay (ECLIA)

Reporting Name

SARS-CoV-2 Spike Ab, Semi-Quant, S

Specimen Type

Serum

Specimen Minimum Volume

0.75 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
  Frozen  28 days
  Ambient  72 hours

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has received Emergency Use Authorization (EUA) by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86769

LOINC Code Information

Test ID Test Order Name Order LOINC Value
COVSQ SARS-CoV-2 Spike Ab, Semi-Quant, S 94769-7

 

Result ID Test Result Name Result LOINC Value
COVIN SARS-CoV-2 Spike Ab, Interp, S 94661-6
COVQN SARS-CoV-2 Spike Ab, Quant, S 94769-7
SRACE Patient's Race 72826-1
SETHN Patient's Ethnicity 69490-1

NY State Approved

Yes

Day(s) Performed

Monday through Saturday

Report Available

1 to 3 days