Test ID BRAZR Brazil Nut, IgE with Reflex to Brazil Nut Component, IgE, Serum
Ordering Guidance
For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies.
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.6 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Useful For
Evaluation of patients with suspected Brazil nut allergy
Highlights
The determination of the relative amount of IgE antibody to total Brazil nut, and IgE antibodies to the specific Brazil nut component, may aid in assessment of the potential strength and type of allergenic response to Brazil nut.
IgE antibody to total Brazil nut will be initially tested.
If detectable total Brazil nut IgE antibody is present, an additional specific component to the Brazil nut allergen antibody testing will be performed. This is comprised of testing for IgE antibodies to the potential allergen Ber e 1.
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
BRAZX | Brazil Nut Component, IgE, S | No | No |
Testing Algorithm
Testing begins with analysis of Brazil nut-specific total IgE. If the Brazil nut-specific total IgE result is negative (<0.10 kU/L), testing is complete.
If the Brazil nut-specific total IgE result is 0.10 kU/L or more, then the Brazil nut component (Ber e 1) test will be performed at an additional charge.
Special Instructions
Method Name
Fluorescent Enzyme Immunoassay (FEIA)
Reporting Name
Brazil Nut Component Reflex, SSpecimen Type
SerumSpecimen Minimum Volume
0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 90 days |
Reference Values
Class |
IgE kU/L |
Interpretation |
0 |
<0.10 |
Negative |
0/1 |
0.10-0.34 |
Borderline/Equivocal |
1 |
0.35-0.69 |
Equivocal |
2 |
0.70-3.49 |
Positive |
3 |
3.50-17.4 |
Positive |
4 |
17.5-49.9 |
Strongly positive |
5 |
50.0-99.9 |
Strongly positive |
6 |
≥100 |
Strongly positive |
Concentrations of 0.70 kU/L or more (class 2 and above) will flag as abnormally high.
Reference values apply to all ages.
Day(s) Performed
Monday through Friday
Report Available
Same day/1 to 3 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
86003
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
BRAZR | Brazil Nut Component Reflex, S | 6050-9 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
BRAZ1 | Brazil Nut, IgE, S | 6050-9 |
NY State Approved
YesForms
If not ordering electronically, complete, print, and send an Allergen Test Request (T236) with the specimen.