Test ID ACMFS Acetylcholine Receptor Modulating Antibody, Flow Cytometry Assay, Serum
Ordering Guidance
Typically, physicians will order acetylcholine receptor (AChR) binding, blocking, and modulating antibodies. Mayo Clinic Laboratories' (MCL) tests are not named in that manner; instead these are offered as myasthenia gravis (MG) evaluations. MGMR / Myasthenia Gravis Evaluation with Muscle-Specific Kinase (MuSK) Reflex, Serum is the testing of choice in most cases.
AChR blocking antibody testing is no longer offered individually as it offers no added-value to the diagnosis and management of MG.
Specimen Required
Only orderable as part of a profile. For more information see:
MGLE / Myasthenia Gravis/Lambert-Eaton Myasthenic Syndrome Evaluation, Serum
MGMR / Myasthenia Gravis Evaluation with Muscle-Specific Kinase (MuSK) Reflex, Serum
PAVAL / Paraneoplastic, Autoantibody Evaluation, Serum
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Useful For
Diagnosis for autoimmune myasthenia gravis (MG) in adults and children
Distinguishing autoimmune from congenital MG in adults and children or other acquired forms of neuromuscular junction transmission disorders.
This test is a qualitative assay and should not be used for monitoring purposes.
Method Name
Only orderable as part of a profile. For more information see:
MGLE / Myasthenia Gravis/Lambert-Eaton Myasthenic Syndrome Evaluation, Serum
MGMR / Myasthenia Gravis Evaluation with Muscle-Specific Kinase (MuSK) Reflex, Serum
PAVAL / Paraneoplastic, Autoantibody Evaluation, Serum
Flow Cytometry
Reporting Name
AChR Modulating Flow Cytometry, SSpecimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 28 days | |
Frozen | 28 days | ||
Ambient | 72 hours |
Reference Values
Only orderable as part of a profile. For more information see:
MGLE / Myasthenia Gravis/Lambert-Eaton Myasthenic Syndrome Evaluation, Serum
MGMR / Myasthenia Gravis Evaluation with Muscle-Specific Kinase (MuSK) Reflex, Serum
PAVAL / Paraneoplastic, Autoantibody Evaluation, Serum
Negative
Day(s) Performed
Monday, Wednesday, Saturday
Report Available
5 to 8 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
86043
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
ACMFS | AChR Modulating Flow Cytometry, S | 99062-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
610029 | AChR Modulating Flow Cytometry, S | 99062-2 |